Cardiff University | Prifysgol Caerdydd ORCA
Online Research @ Cardiff 
WelshClear Cookie - decide language by browser settings

Polarimetry at millimeter wavelengths with the NIKA camera: calibration and performance

Ritacco, A, Ponthieu, N, Catalano, A, Adam, R, Ade, P, André, P, Beelen, A, Benoît, A, Bideaud, A, N. Billot, N, Bourrion, O, Calvo, M, Coiffard, G, Comis, B, Désert, F.X., Doyle, Simon ORCID: https://orcid.org/0000-0002-9054-986X, Goupy, G, Kramer, C, Leclercq, S, Macías-Pérez, J.F., Mauskopf, P, Maury, A, Mayet, F, Monfardini, A, Pajot, F, Pascale, E, Perotto, L, Pisano, Giampaolo ORCID: https://orcid.org/0000-0003-4302-5681, Rebolo-Iglesias, M, Revéret, V, Rodriguez, L, Romero, C, Ruppin, F, Savini, G, Schuster, K, Sievers, A, Thum, C, Triqueneaux, S, Tucker, C and Zylka, R 2017. Polarimetry at millimeter wavelengths with the NIKA camera: calibration and performance. Astronomy and Astrophysics 599 , A34. 10.1051/0004-6361/201629666

[thumbnail of NIKA_AandA_Polarimetry_2017.pdf]
Preview
PDF - Published Version
Download (8MB) | Preview

Abstract

Magnetic fields, which play a major role in a large number of astrophysical processes can be traced via observations of dust polar- ization. In particular, Planck low-resolution observations of dust polarization have demonstrated that Galactic filamentary structures, where star formation takes place, are associated to well organized magnetic fields. A better understanding of this process requires detailed observations of galactic dust polarization on scales of 0.01 to 0.1 pc. Such high-resolution polarization observations can be carried out at the IRAM 30 m telescope using the recently installed NIKA2 camera, which features two frequency bands at 260 and 150 GHz (respectively 1.15 and 2.05 mm), the 260 GHz band being polarization sensitive. NIKA2 so far in commissioning phase, has its focal plane filled with ∼3300 detectors to cover a Field of View (FoV) of 6.5 arcmin diameter. The NIKA camera, which consisted of two arrays of 132 and 224 Lumped Element Kinetic Inductance Detectors (LEKIDs) and a FWHM (Full-Width-Half-Maximum) of 12 and 18.2 arcsec at 1.15 and 2.05 mm respectively, has been operated at the IRAM 30 m telescope from 2012 to 2015 as a test-bench for NIKA2. NIKA was equipped of a room temperature polarization system (a half wave plate (HWP) and a grid polarizer facing the NIKA cryostat window). The fast and continuous rotation of the HWP permits the quasi simultaneous reconstruction of the three Stokes parameters, I, Q, and U at 150 and 260 GHz. This paper presents the first polarization measurements with KIDs and reports the polarization performance of the NIKA camera and the pertinence of the choice of the polarization setup in the perspective of NIKA2. We describe the polarized data reduction pipeline, specifically developed for this project and how the continuous rotation of the HWP permits to shift the polarized signal far from any low frequency noise. We also present the dedicated algorithm developed to correct systematic leakage effects. We report results on compact and extended sources obtained during the February 2015 technical campaign. These results demonstrate a good understanding of polarization systematics and state-of-the-art performance in terms of photometry, polarization degree and polarization angle reconstruction.

Item Type: Article
Date Type: Published Online
Status: Published
Schools: Physics and Astronomy
Subjects: Q Science > QB Astronomy
Publisher: EDP Sciences
ISSN: 0004-6361
Date of First Compliant Deposit: 12 June 2017
Date of Acceptance: 3 December 2016
Last Modified: 05 May 2023 11:36
URI: https://orca.cardiff.ac.uk/id/eprint/99868

Citation Data

Cited 22 times in Scopus. View in Scopus. Powered By Scopus® Data

Actions (repository staff only)

Edit Item Edit Item

Downloads

Downloads per month over past year

View more statistics