Cardiff University | Prifysgol Caerdydd ORCA
Online Research @ Cardiff 
WelshClear Cookie - decide language by browser settings

The silicon cold-electron bolometer

Brien, Thomas 2015. The silicon cold-electron bolometer. PhD Thesis, Cardiff University and Warwick University.
Item availability restricted.

[thumbnail of 2015BrienPhD SIGS REMOVED.pdf]
Preview
PDF - Accepted Post-Print Version
Available under License Creative Commons Attribution Non-commercial.

Download (6MB) | Preview
[thumbnail of BrienT.pdf] PDF - Supplemental Material
Restricted to Repository staff only

Download (103kB) | Request a copy

Abstract

This thesis describes the development and testing of two cold-electron bolometers using highly-doped silicon as the absorber. These detectors exhibit both high sensitivity and low time constants. High sensitivity is achieved due to the weak thermal-link between the electrons and the phonons in the silicon absorber at low temperature (< 1 K). Schottky barriers form naturally between the highly-doped silicon absorber and the superconducting contacts. Selective tunnelling of electrons across these Schottky barriers allows the electron temperature in the silicon absorber to be cooled to below the thermal bath temperature. This direct electron-cooling acts as thermoelectric feedback, reducing the time constant of a cold-electron bolometer to below 1 µs. In this work, the underlying physics of these devices is discussed and two devices are presented: one with a highly-doped silicon absorber and the other with strained highly-doped silicon used as the absorber. The design of these detectors is discussed and results are found from numerous characterisation experiments, including optical measurements. These measurements show that a prototype device, using a strained and highly-doped silicon absorber, has a noise-equivalent power of 6.6 × 10^-17 W/rtHz. When photon noise (which dominated this measurement) and noise from the amplifier are disregarded, the underlying device-limited noise-equivalent power is 2.0 × 10^-17 W/rtHz. By measuring the photon noise, the time constant of this detector has been determined to be less than 1.5 µs. When compared to the device using unstrained silicon, it is clear that the straining of the silicon absorber, which reduces the electron-phonon coupling, produces a notable improvement in detector performance. Furthermore, a novel amplifier-readout technique, whereby the outputs of two matched amplifiers are cross correlated is introduced; this technique reduces the input-referred amplifier noise from 1 nV/rtHz to 300 pV/rtHz.

Item Type: Thesis (PhD)
Status: Unpublished
Schools: Engineering
Physics and Astronomy
Subjects: Q Science > QB Astronomy
Uncontrolled Keywords: Astronomical Instrumentation, Detectors, Electron-Phonon Interaction, Strained Silicon, Readout Electronics.
Funders: Cardiff University & Warwick University
Date of First Compliant Deposit: 30 March 2016
Last Modified: 15 Aug 2023 08:17
URI: https://orca.cardiff.ac.uk/id/eprint/77064

Actions (repository staff only)

Edit Item Edit Item

Downloads

Downloads per month over past year

View more statistics