Cardiff University | Prifysgol Caerdydd ORCA
Online Research @ Cardiff 
WelshClear Cookie - decide language by browser settings

Usefulness of I-124 PET/CT imaging to predict absorbed doses in patients affected by metastatic thyroid cancer and treated with I-131

Pettinato, C., Monari, F., Nanni, C., Allegri, V., Marcatili, S., Civollani, S., Cima, S., Spezi, Emiliano ORCID: https://orcid.org/0000-0002-1452-8813, Mazzarotto, R. and Fanti, S. 2012. Usefulness of I-124 PET/CT imaging to predict absorbed doses in patients affected by metastatic thyroid cancer and treated with I-131. Quarterly journal of nuclear medicine and molecular imaging 56 (6) , pp. 509-514.

Full text not available from this repository.

Abstract

AIM: The aim of this work was the evaluation of the usefulness of 124I PET/CT sequential scans to predict absorbed doses to metastatic thyroid cancer in patients undergoing 131I therapy. METHODS: From July 2011 until April 2012 8 patients affected by metastatic thyroid cancer were enrolled. Each patient underwent 4 PET/CT scans at 4, 24, 48, 72 h after the administration of about 74 MBq of 124I. Blood samples and whole body exposure measurements were obtained to calculate blood and red marrow doses. Activity concentrations and lesion volumes obtained from PET/CT images were used to evaluate tumour doses with MIRD formalism and spheres model. The average administered 131I therapeutic activity was 6475 MBq (range: 3700-9250 MBq). RESULTS: 124I PET/CT images showed, with a very good resolution, all 131I avid lesions detected by post therapy whole body scans. The average dose rates for blood, red marrow and lesions were respectively: 6.58E-02 ± 1.64E-02 mGy/MBq, 5.73E-02 ± 1.57E-02 mGy/MBq, 2.22E+01 ± 1.62E+01 mGy/MBq. Three out of eight patients did not show any uptake of 124I in all PET/CT scans, despite high level of TSH and CT detectable lesions. Post-therapy 131I whole body scan confirmed the absence of focal iodine uptake. CONCLUSION: Negative 124I PET/CT images probably could be used as predictive of real absence of iodine avidity, avoiding all toxicity from useless 131I therapy. A higher number of patients is necessary to validate these preliminary results and a project is ongoing to compare MIRD results to voxel dosimetry based on Monte Carlo simulation.

Item Type: Article
Date Type: Publication
Status: Published
Schools: Engineering
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
Publisher: Edizioni Minerva Medica
ISSN: 1824-4785
Related URLs:
Last Modified: 28 Oct 2022 08:52
URI: https://orca.cardiff.ac.uk/id/eprint/72455

Actions (repository staff only)

Edit Item Edit Item