A GC-TOF-MS study of the stability of serum and urine metabolomes during the UK Biobank sample collection and preparation protocols

Dunn, Warwick B., Broadhurst, David, Ellis, David I., Brown, Marie, Halsall, Anthony, O'Hagan, Steven, Spasic, Irena ORCID: https://orcid.org/0000-0002-8132-3885, Tseng, Andrew and Kell, Douglas B. 2008. A GC-TOF-MS study of the stability of serum and urine metabolomes during the UK Biobank sample collection and preparation protocols. International Journal of Epidemiology 37 (S1) , i23-i30. 10.1093/ije/dym281

Full text not available from this repository.

Abstract

BACKGROUND: The stability of mammalian serum and urine in large metabolomic investigations is essential for accurate, valid and reproducible studies. The stability of mammalian serum and urine, either processed immediately by freezing at -80 degrees C or stored at 4 degrees C for 24 h before being frozen, was compared in a pilot metabolomic study of samples from 40 separate healthy volunteers. METHODS: Metabolic profiling with GC-TOF-MS was performed for serum and urine samples collected from 40 volunteers and stored at -80 degrees C or 4 degrees C for 24 h before being frozen at -80 degrees C. Subsequent Wilcoxon rank sum test and Principal Components Analysis (PCA) methods were used to assess whether differences in the metabolomes were detected between samples stored at 4 degrees C for 0 or 24 h. RESULTS: More than 700 unique metabolite peaks were detected, with over 200 metabolite peaks detected in any one sample. PCA and Wilcoxon rank sum tests of serum and urine data showed as a general observation that the variance associated with the replicate analysis per sample (analytical variance) was of the same magnitude as the variance observed between samples stored at 4 degrees C for 0 or 24 h. From a functional point of view the metabolomic composition of the majority of samples did not change in a statistically significant manner when stored under two different conditions. CONCLUSIONS: Based on this small pilot study, the UK Biobank sampling, transport and fractionation protocols are considered suitable to provide samples, which can produce scientifically robust and valid data in metabolomic studies.

Item Type: Article
Date Type: Publication
Status: Published
Schools: Computer Science & Informatics
Subjects: Q Science > QA Mathematics > QA75 Electronic computers. Computer science
Uncontrolled Keywords: Mcisb; Spasic; Metabolomics; Metabolic profiling; GC-MS; Univariate analysis; Multivariate analysis; Biofluid serum; Urine
Publisher: Oxford University Press
ISSN: 1464-3685
Last Modified: 17 Oct 2022 09:56
URI: https://orca.cardiff.ac.uk/id/eprint/6214

Citation Data

Cited 117 times in Scopus. View in Scopus. Powered By Scopus® Data

Actions (repository staff only)

Edit Item Edit Item