Cardiff University | Prifysgol Caerdydd ORCA
Online Research @ Cardiff 
WelshClear Cookie - decide language by browser settings

The effect of pre-adapting light intensity on dark adaptation in early age-related macular degeneration

Gaffney, Allannah J., Binns, Alison and Margrain, Thomas Hengist ORCID: https://orcid.org/0000-0003-1280-0809 2013. The effect of pre-adapting light intensity on dark adaptation in early age-related macular degeneration. Documenta Ophthalmologica 127 (3) , pp. 191-199. 10.1007/s10633-013-9400-3

Full text not available from this repository.

Abstract

Background: This study aimed to identify the pre-adapting light intensity that generated the maximum separation in the parameters of dark adaptation between participants with early age-related macular degeneration (AMD) and healthy control participants in the minimum recording time. Methods: Cone dark adaptation was monitored in 10 participants with early AMD and 10 age-matched controls after exposure to three pre-adapting light intensities, using an achromatic annulus (12° radius) centred on the fovea. Threshold recovery data were modelled, and the time constant of cone recovery (τ), final cone threshold, and time to rod-cone-break (RCB) were determined. The diagnostic potential of these parameters at all pre-adapting intensities was evaluated by constructing receiver operating characteristic (ROC) curves. Results: There were significant differences between those with early AMD and healthy controls in cone τ and time to RCB (p < 0.05) at all pre-adapting ‘bleaching’ intensities. ROC curves showed that the diagnostic potential of dark adaptometry was high following exposure to all three pre-adapting intensities, generating an area under the curve in excess of 0.87 ± 0.08 for cone τ and time to RCB for all conditions. Conclusions: Dark adaptation was shown to be highly diagnostic for early AMD across a range of pre-adapting light intensities, and therefore, the lower pre-adapting intensities evaluated in this study may be used to expedite dark adaptation measurement in the clinic without compromising the integrity of the data obtained. This study reinforces the suggestion that cone and rod dark adaptation are good candidate biomarkers for early AMD.

Item Type: Article
Date Type: Publication
Status: Published
Schools: Optometry and Vision Sciences
Subjects: R Medicine > RE Ophthalmology
Publisher: Springer
ISSN: 0012-4486
Last Modified: 25 Oct 2022 08:35
URI: https://orca.cardiff.ac.uk/id/eprint/53525

Citation Data

Cited 10 times in Scopus. View in Scopus. Powered By Scopus® Data

Actions (repository staff only)

Edit Item Edit Item