Cardiff University | Prifysgol Caerdydd ORCA
Online Research @ Cardiff 
WelshClear Cookie - decide language by browser settings

Clinical aspects of Critical Flicker Fusion perimetry: an in-depth analysis

Luraas, Knut 2012. Clinical aspects of Critical Flicker Fusion perimetry: an in-depth analysis. PhD Thesis, Cardiff University.
Item availability restricted.

[thumbnail of Luraas - Knut - Electronic publication form.pdf] PDF - Supplemental Material
Restricted to Repository staff only

Download (683kB)
[thumbnail of Luraas - Knut  Thesis (1) dec page removed.pdf]
Preview
PDF - Accepted Post-Print Version
Download (8MB) | Preview

Abstract

The thesis evaluated, in three studies, the clinical potential of Critical Flicker Fusion perimetry (CFFP) undertaken using the Octopus 311 perimeter. The influence of the learning effect on the outcome of CFFP was evaluated, in each eye at each of five visits each separated by one week, for 28 normal individuals naïve to perimetry, 10 individuals with ocular hypertension (OHT) and 11 with open angle glaucoma (OAG) all of whom were experienced in Standard Automated perimetry (SAP). An improvement occurred in the height, rather than in the shape, of the visual field and was largest for those with OAG. The normal individuals reached optimum performance at the third visit and those with OHT or with OAG at the fourth or fifth visits. The influence of ocular media opacity was investigated in 22 individuals with age-related cataract who were naïve to both SAP and CFFP. All individuals underwent both CFFP and SAP in each eye at each of four visits each separated by one week. At the third and fourth visit, glare disability (GD) was measured with 100% and 10% contrast EDTRS LogMAR visual acuity charts in the presence, and absence, of three levels of glare using the Brightness Acuity Tester. The visual field for CFF improved in height, only. Little correlation was present between the various measures of GD and the visual field, largely due to the narrow range of cataract severity. The influence of optical defocus for both CFFP and SAP was investigated, in one designated eye at each of two visits, in 16 normal individuals all of whom had taken part in the first study. Sensitivity for SAP declined with increase in defocus whilst that for CFFP increased. The latter was attributed to the influence of the Granit-Harper Law arising from the increased size of the defocused stimulus.

Item Type: Thesis (PhD)
Status: Unpublished
Schools: Optometry and Vision Sciences
Subjects: R Medicine > RE Ophthalmology
Uncontrolled Keywords: CFF perimetry ; SAP ; TOP ; learning effect ; ocular media opacity ; defocus
Date of First Compliant Deposit: 30 March 2016
Last Modified: 13 Sep 2023 12:32
URI: https://orca.cardiff.ac.uk/id/eprint/39684

Actions (repository staff only)

Edit Item Edit Item

Downloads

Downloads per month over past year

View more statistics